GPY208 Hydraulic Static Pile Driver
GPY208 Hydraulic Static Pile Driver
GPY208 Hydraulic Static Pile Driver
GPY208 Hydraulic Static Pile Driver
+
  • GPY208 Hydraulic Static Pile Driver
  • GPY208 Hydraulic Static Pile Driver
  • GPY208 Hydraulic Static Pile Driver
  • GPY208 Hydraulic Static Pile Driver

GPY208 Hydraulic Static Pile Driver

The GPY208 hydraulic static pile driver is designed for pressing precast concrete foundation piles without impact hammering. Its listed maximum pile pressing force is 208 tf. The hydraulic pile pressing mechanism supports controlled installation for building foundation projects, while the side and corner piling arrangement can help on sites where pile positions are close to boundaries. The precise pile size range, piling speed and minimum side/corner clearances depend on the supplied version and should be confirmed against the final technical sheet. • Maximum pile pressing force: 208 tf • High/low piling speeds: 9.2 / 1.4 m/min • 1.6 m piling stroke • Square pile range: 200–400 mm • Round pile range: Φ300–Φ400 mm • Side piling space: 0.6 m • Corner piling space: 0.9 m • Modular structure for easier transport and assembly Precast concrete pile foundations; urban building foundations; industrial plants; residential projects; low-noise foundation construction; sites requiring side and corner piling.   MAIN TECHNICAL SPECIFICATIONS Parameter Unit GPY208 Max. Pile Pressing Force tf 208 Piling Speed - High m/min 9.2 Piling Speed - Low m/min 1.4 Piling Stroke m 1.6 Longitudinal Travel per Step m 2.2 Horizontal Travel per Step m 0.4 Machine Rotation Angle ° 13 Leg Lifting Stroke m 1.58 Pile Clamping Box   4022 Square Pile - Minimum mm 200 Square Pile - Maximum mm 400 Round Pile - Minimum mm Φ300 Round Pile - Maximum mm Φ400 Side Piling Space m 0.6 Corner Piling Space m 0.9 Lifting Capacity T 12 Hoisting Pile Length m 14 Ground Pressure - Long Bridge kPa 147 Ground Pressure - Short Bridge kPa 122 Overall Dimensions (L×W×H) m 10 × 5.18 × 3.5

WeChat:

Product Details


  • Product Description
  • The GPY208 hydraulic static pile driver is designed for pressing precast concrete foundation piles without impact hammering. Its listed maximum pile pressing force is 208 tf. The hydraulic pile pressing mechanism supports controlled installation for building foundation projects, while the side and corner piling arrangement can help on sites where pile positions are close to boundaries. The precise pile size range, piling speed and minimum side/corner clearances depend on the supplied version and should be confirmed against the final technical sheet.

    • Maximum pile pressing force: 208 tf
    • High/low piling speeds: 9.2 / 1.4 m/min
    • 1.6 m piling stroke
    • Square pile range: 200–400 mm
    • Round pile range: Φ300–Φ400 mm
    • Side piling space: 0.6 m
    • Corner piling space: 0.9 m
    • Modular structure for easier transport and assembly

    Precast concrete pile foundations; urban building foundations; industrial plants; residential projects; low-noise foundation construction; sites requiring side and corner piling.

     

    MAIN TECHNICAL SPECIFICATIONS
    Parameter Unit GPY208
    Max. Pile Pressing Force tf 208
    Piling Speed - High m/min 9.2
    Piling Speed - Low m/min 1.4
    Piling Stroke m 1.6
    Longitudinal Travel per Step m 2.2
    Horizontal Travel per Step m 0.4
    Machine Rotation Angle ° 13
    Leg Lifting Stroke m 1.58
    Pile Clamping Box   4022
    Square Pile - Minimum mm 200
    Square Pile - Maximum mm 400
    Round Pile - Minimum mm Φ300
    Round Pile - Maximum mm Φ400
    Side Piling Space m 0.6
    Corner Piling Space m 0.9
    Lifting Capacity T 12
    Hoisting Pile Length m 14
    Ground Pressure - Long Bridge kPa 147
    Ground Pressure - Short Bridge kPa 122
    Overall Dimensions (L×W×H) m 10 × 5.18 × 3.5

Product Q&A


What working conditions are horizontal directional drilling rigs primarily used for?

It is primarily used for trenchless installation of underground pipelines and is suitable for the construction of crossings for telecommunications, gas, and water supply and drainage pipelines.

Can a horizontal directional drilling rig penetrate both soil and rock formations?

Standard models are suitable for soil layers; for rock formations, a rock‑drilling attachment kit must be selected.

What is the maximum drilling depth achievable by a water well drilling rig?

Drilling depths vary by model; standard models cover 100–350 meters, with options available to suit specific requirements.

Is the water well drilling rig hydraulically driven, and does it support a diesel engine as its power source?

The entire machine is hydraulically driven and can be equipped with either a diesel engine or an electric motor as its power source.

Is a drilling rig suitable for constructing rural drinking-water wells and engineering dewatering wells?

Fully applicable and widely used for domestic drinking wells, agricultural irrigation wells, and construction dewatering wells.

Is the wheeled pile driver easy to move, and does it require trailer transport?

The wheeled chassis is self-propelled and can move under its own power over short distances; for long-distance transport, towing is recommended.

GPY208 Hydraulic Static Pile Driver

The GPY208 hydraulic static pile driver is designed for pressing precast concrete foundation piles without impact hammering. Its listed maximum pile pressing force is 208 tf. The hydraulic pile pressing mechanism supports controlled installation for building foundation projects, while the side and corner piling arrangement can help on sites where pile positions are close to boundaries. The precise pile size range, piling speed and minimum side/corner clearances depend on the supplied version and should be confirmed against the final technical sheet. • Maximum pile pressing force: 208 tf • High/low piling speeds: 9.2 / 1.4 m/min • 1.6 m piling stroke • Square pile range: 200–400 mm • Round pile range: Φ300–Φ400 mm • Side piling space: 0.6 m • Corner piling space: 0.9 m • Modular structure for easier transport and assembly Precast concrete pile foundations; urban building foundations; industrial plants; residential projects; low-noise foundation construction; sites requiring side and corner piling.   MAIN TECHNICAL SPECIFICATIONS Parameter Unit GPY208 Max. Pile Pressing Force tf 208 Piling Speed - High m/min 9.2 Piling Speed - Low m/min 1.4 Piling Stroke m 1.6 Longitudinal Travel per Step m 2.2 Horizontal Travel per Step m 0.4 Machine Rotation Angle ° 13 Leg Lifting Stroke m 1.58 Pile Clamping Box   4022 Square Pile - Minimum mm 200 Square Pile - Maximum mm 400 Round Pile - Minimum mm Φ300 Round Pile - Maximum mm Φ400 Side Piling Space m 0.6 Corner Piling Space m 0.9 Lifting Capacity T 12 Hoisting Pile Length m 14 Ground Pressure - Long Bridge kPa 147 Ground Pressure - Short Bridge kPa 122 Overall Dimensions (L×W×H) m 10 × 5.18 × 3.5

WeChat:


Product Services

We offer a wealth of product support resources, including a wide range of technical documentation, downloadable product manuals, and product certification documents.

Service Support

Equipment Quotation Request

Please provide your phone number and email address so we can contact you promptly and resolve your issue as soon as possible.

Submit Message